Standard

Quality assessment of digital X-ray chest images using an anthropomorphic chest phantom. / Vodovatov, A. V.; Kamishanskaya, I. G.; Drozdov, A. A.; Bernhardsson, C.

In: Journal of Physics: Conference Series, Vol. 808, No. 1, 012009, 21.02.2017.

Research output: Contribution to journalConference articlepeer-review

Harvard

APA

Vancouver

Author

Vodovatov, A. V. ; Kamishanskaya, I. G. ; Drozdov, A. A. ; Bernhardsson, C. / Quality assessment of digital X-ray chest images using an anthropomorphic chest phantom. In: Journal of Physics: Conference Series. 2017 ; Vol. 808, No. 1.

BibTeX

@article{5751c95d42634019b39d3cd7d5814139,
title = "Quality assessment of digital X-ray chest images using an anthropomorphic chest phantom",
abstract = "The current study is focused on determining the optimal tube voltage for the conventional X-ray digital chest screening examinations, using a visual grading analysis method. Chest images of an anthropomorphic phantom were acquired in posterior-anterior projection on four digital X-ray units with different detector types. X-ray images obtained with an anthropomorphic phantom were accepted by the radiologists as corresponding to a normal human anatomy, hence allowing using phantoms in image quality trials without limitations.",
author = "Vodovatov, {A. V.} and Kamishanskaya, {I. G.} and Drozdov, {A. A.} and C. Bernhardsson",
note = "Publisher Copyright: {\textcopyright} Published under licence by IOP Publishing Ltd. Copyright: Copyright 2018 Elsevier B.V., All rights reserved.; 3rd International Conference on X-Ray Technique ; Conference date: 24-11-2016 Through 25-11-2016",
year = "2017",
month = feb,
day = "21",
doi = "10.1088/1742-6596/808/1/012009",
language = "English",
volume = "808",
journal = "Journal of Physics: Conference Series",
issn = "1742-6588",
publisher = "IOP Publishing Ltd.",
number = "1",

}

RIS

TY - JOUR

T1 - Quality assessment of digital X-ray chest images using an anthropomorphic chest phantom

AU - Vodovatov, A. V.

AU - Kamishanskaya, I. G.

AU - Drozdov, A. A.

AU - Bernhardsson, C.

N1 - Publisher Copyright: © Published under licence by IOP Publishing Ltd. Copyright: Copyright 2018 Elsevier B.V., All rights reserved.

PY - 2017/2/21

Y1 - 2017/2/21

N2 - The current study is focused on determining the optimal tube voltage for the conventional X-ray digital chest screening examinations, using a visual grading analysis method. Chest images of an anthropomorphic phantom were acquired in posterior-anterior projection on four digital X-ray units with different detector types. X-ray images obtained with an anthropomorphic phantom were accepted by the radiologists as corresponding to a normal human anatomy, hence allowing using phantoms in image quality trials without limitations.

AB - The current study is focused on determining the optimal tube voltage for the conventional X-ray digital chest screening examinations, using a visual grading analysis method. Chest images of an anthropomorphic phantom were acquired in posterior-anterior projection on four digital X-ray units with different detector types. X-ray images obtained with an anthropomorphic phantom were accepted by the radiologists as corresponding to a normal human anatomy, hence allowing using phantoms in image quality trials without limitations.

UR - http://www.scopus.com/inward/record.url?scp=85016218103&partnerID=8YFLogxK

U2 - 10.1088/1742-6596/808/1/012009

DO - 10.1088/1742-6596/808/1/012009

M3 - Conference article

AN - SCOPUS:85016218103

VL - 808

JO - Journal of Physics: Conference Series

JF - Journal of Physics: Conference Series

SN - 1742-6588

IS - 1

M1 - 012009

T2 - 3rd International Conference on X-Ray Technique

Y2 - 24 November 2016 through 25 November 2016

ER -