Standard

Photocurable membranes for ion-selective light-addressable potentiometric sensor. / Ermolenko, Y; Yoshinobu, T; Mourzina, Y; Levichev, S; Furuichi, K; Vlasov, Y; Schoning, MJ; Iwasaki, H.

In: Sensors and Actuators, B: Chemical, Vol. 85, No. 1-2, PII S0925-4005(02)00056-4, 20.06.2002, p. 79-85.

Research output: Contribution to journalArticlepeer-review

Harvard

Ermolenko, Y, Yoshinobu, T, Mourzina, Y, Levichev, S, Furuichi, K, Vlasov, Y, Schoning, MJ & Iwasaki, H 2002, 'Photocurable membranes for ion-selective light-addressable potentiometric sensor', Sensors and Actuators, B: Chemical, vol. 85, no. 1-2, PII S0925-4005(02)00056-4, pp. 79-85. https://doi.org/10.1016/S0925-4005(02)00056-4

APA

Ermolenko, Y., Yoshinobu, T., Mourzina, Y., Levichev, S., Furuichi, K., Vlasov, Y., Schoning, MJ., & Iwasaki, H. (2002). Photocurable membranes for ion-selective light-addressable potentiometric sensor. Sensors and Actuators, B: Chemical, 85(1-2), 79-85. [PII S0925-4005(02)00056-4]. https://doi.org/10.1016/S0925-4005(02)00056-4

Vancouver

Ermolenko Y, Yoshinobu T, Mourzina Y, Levichev S, Furuichi K, Vlasov Y et al. Photocurable membranes for ion-selective light-addressable potentiometric sensor. Sensors and Actuators, B: Chemical. 2002 Jun 20;85(1-2):79-85. PII S0925-4005(02)00056-4. https://doi.org/10.1016/S0925-4005(02)00056-4

Author

Ermolenko, Y ; Yoshinobu, T ; Mourzina, Y ; Levichev, S ; Furuichi, K ; Vlasov, Y ; Schoning, MJ ; Iwasaki, H. / Photocurable membranes for ion-selective light-addressable potentiometric sensor. In: Sensors and Actuators, B: Chemical. 2002 ; Vol. 85, No. 1-2. pp. 79-85.

BibTeX

@article{2d000bf216dd47d3a2272c02d3159327,
title = "Photocurable membranes for ion-selective light-addressable potentiometric sensor",
abstract = "A new type of light-addressable potentiometric sensor (LAPS) has been developed by elaboration of photocurable ion-sensitive membranes based on matrices of mono- and diacrylates in combination with a silicon-based electrochemical transducer for the purposes of chemical and biochemical analyses. The characteristics of the elaborated K-, Li-, Cs-, Ca- and Mg-LAPS are presented to indicate the potential of the technology developed. For example, the sensitivities of the K- and Li-LAPS were found to be 58 +/- 1 mV/pK and 59 +/- 1 mV/pLi, respectively, over concentration ranges of 10(-5)-10(-1) mol/l. The detection limits were evaluated to be 2 x 10(-6) mol/l of the primary ion. (C) 2002 Elsevier Science B.V. All rights reserved.",
keywords = "light-addressable potentiometric sensor (LAPS), photocurable membranes, ion-sensitivity, POTASSIUM, ELECTRODE",
author = "Y Ermolenko and T Yoshinobu and Y Mourzina and S Levichev and K Furuichi and Y Vlasov and MJ Schoning and H Iwasaki",
year = "2002",
month = jun,
day = "20",
doi = "10.1016/S0925-4005(02)00056-4",
language = "Английский",
volume = "85",
pages = "79--85",
journal = "Sensors and Actuators, B: Chemical",
issn = "0925-4005",
publisher = "Elsevier",
number = "1-2",

}

RIS

TY - JOUR

T1 - Photocurable membranes for ion-selective light-addressable potentiometric sensor

AU - Ermolenko, Y

AU - Yoshinobu, T

AU - Mourzina, Y

AU - Levichev, S

AU - Furuichi, K

AU - Vlasov, Y

AU - Schoning, MJ

AU - Iwasaki, H

PY - 2002/6/20

Y1 - 2002/6/20

N2 - A new type of light-addressable potentiometric sensor (LAPS) has been developed by elaboration of photocurable ion-sensitive membranes based on matrices of mono- and diacrylates in combination with a silicon-based electrochemical transducer for the purposes of chemical and biochemical analyses. The characteristics of the elaborated K-, Li-, Cs-, Ca- and Mg-LAPS are presented to indicate the potential of the technology developed. For example, the sensitivities of the K- and Li-LAPS were found to be 58 +/- 1 mV/pK and 59 +/- 1 mV/pLi, respectively, over concentration ranges of 10(-5)-10(-1) mol/l. The detection limits were evaluated to be 2 x 10(-6) mol/l of the primary ion. (C) 2002 Elsevier Science B.V. All rights reserved.

AB - A new type of light-addressable potentiometric sensor (LAPS) has been developed by elaboration of photocurable ion-sensitive membranes based on matrices of mono- and diacrylates in combination with a silicon-based electrochemical transducer for the purposes of chemical and biochemical analyses. The characteristics of the elaborated K-, Li-, Cs-, Ca- and Mg-LAPS are presented to indicate the potential of the technology developed. For example, the sensitivities of the K- and Li-LAPS were found to be 58 +/- 1 mV/pK and 59 +/- 1 mV/pLi, respectively, over concentration ranges of 10(-5)-10(-1) mol/l. The detection limits were evaluated to be 2 x 10(-6) mol/l of the primary ion. (C) 2002 Elsevier Science B.V. All rights reserved.

KW - light-addressable potentiometric sensor (LAPS)

KW - photocurable membranes

KW - ion-sensitivity

KW - POTASSIUM

KW - ELECTRODE

U2 - 10.1016/S0925-4005(02)00056-4

DO - 10.1016/S0925-4005(02)00056-4

M3 - статья

VL - 85

SP - 79

EP - 85

JO - Sensors and Actuators, B: Chemical

JF - Sensors and Actuators, B: Chemical

SN - 0925-4005

IS - 1-2

M1 - PII S0925-4005(02)00056-4

ER -

ID: 5089151