Standard
Multi-channel neutron guides of PNPI : results of neutron and X-ray reflectometry tests. / Schebetov, A.; Kovalev, A.; Peskov, B.; Pleshanov, N.; Pusenkov, V.; Schubert-Bischoff, P.; Shmelev, G.; Soroko, Z.; Syromyatnikov, V.; Ul'yanov, V.; Zaitsev, A.
In:
Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 432, No. 2-3, 11.08.1999, p. 214-226.
Research output: Contribution to journal › Article › peer-review
Harvard
Schebetov, A, Kovalev, A, Peskov, B
, Pleshanov, N, Pusenkov, V, Schubert-Bischoff, P, Shmelev, G, Soroko, Z
, Syromyatnikov, V, Ul'yanov, V & Zaitsev, A 1999, '
Multi-channel neutron guides of PNPI: results of neutron and X-ray reflectometry tests',
Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, vol. 432, no. 2-3, pp. 214-226.
https://doi.org/10.1016/S0168-9002(99)00480-5
APA
Schebetov, A., Kovalev, A., Peskov, B.
, Pleshanov, N., Pusenkov, V., Schubert-Bischoff, P., Shmelev, G., Soroko, Z.
, Syromyatnikov, V., Ul'yanov, V., & Zaitsev, A. (1999).
Multi-channel neutron guides of PNPI: results of neutron and X-ray reflectometry tests.
Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment,
432(2-3), 214-226.
https://doi.org/10.1016/S0168-9002(99)00480-5
Vancouver
Author
Schebetov, A. ; Kovalev, A. ; Peskov, B.
; Pleshanov, N. ; Pusenkov, V. ; Schubert-Bischoff, P. ; Shmelev, G. ; Soroko, Z.
; Syromyatnikov, V. ; Ul'yanov, V. ; Zaitsev, A. /
Multi-channel neutron guides of PNPI : results of neutron and X-ray reflectometry tests. In:
Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 1999 ; Vol. 432, No. 2-3. pp. 214-226.
BibTeX
@article{b14b9f2da0f74bc7a2a59227ff0d315b,
title = "Multi-channel neutron guides of PNPI: results of neutron and X-ray reflectometry tests",
abstract = "A method to test multichannel neutron guides by means of neutron and X-ray reflectometry has been developed. The method is based on testing single mirrors and then neutron optical systems assembled from them. The method enables to reliably predict the resultant neutron fluxes at the exit of neutron guides. In addition, the experimental transmittances of the multi-channel neutron guides are shown to be close to those calculated on assumption of their perfect geometry.",
author = "A. Schebetov and A. Kovalev and B. Peskov and N. Pleshanov and V. Pusenkov and P. Schubert-Bischoff and G. Shmelev and Z. Soroko and V. Syromyatnikov and V. Ul'yanov and A. Zaitsev",
year = "1999",
month = aug,
day = "11",
doi = "10.1016/S0168-9002(99)00480-5",
language = "English",
volume = "432",
pages = "214--226",
journal = "Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment",
issn = "0168-9002",
publisher = "Elsevier",
number = "2-3",
}
RIS
TY - JOUR
T1 - Multi-channel neutron guides of PNPI
T2 - results of neutron and X-ray reflectometry tests
AU - Schebetov, A.
AU - Kovalev, A.
AU - Peskov, B.
AU - Pleshanov, N.
AU - Pusenkov, V.
AU - Schubert-Bischoff, P.
AU - Shmelev, G.
AU - Soroko, Z.
AU - Syromyatnikov, V.
AU - Ul'yanov, V.
AU - Zaitsev, A.
PY - 1999/8/11
Y1 - 1999/8/11
N2 - A method to test multichannel neutron guides by means of neutron and X-ray reflectometry has been developed. The method is based on testing single mirrors and then neutron optical systems assembled from them. The method enables to reliably predict the resultant neutron fluxes at the exit of neutron guides. In addition, the experimental transmittances of the multi-channel neutron guides are shown to be close to those calculated on assumption of their perfect geometry.
AB - A method to test multichannel neutron guides by means of neutron and X-ray reflectometry has been developed. The method is based on testing single mirrors and then neutron optical systems assembled from them. The method enables to reliably predict the resultant neutron fluxes at the exit of neutron guides. In addition, the experimental transmittances of the multi-channel neutron guides are shown to be close to those calculated on assumption of their perfect geometry.
UR - http://www.scopus.com/inward/record.url?scp=0033169486&partnerID=8YFLogxK
U2 - 10.1016/S0168-9002(99)00480-5
DO - 10.1016/S0168-9002(99)00480-5
M3 - Article
AN - SCOPUS:0033169486
VL - 432
SP - 214
EP - 226
JO - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
JF - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
SN - 0168-9002
IS - 2-3
ER -