Standard

Modification of titanium and titanium dioxide surfaces by ion implantation : Combined XPS and DFT study. / Boukhvalov, D. W.; Korotin, D. M.; Efremov, A. V.; Kurmaev, E. Z.; Borchers, C.; Zhidkov, I. S.; Gunderov, D. V.; Valiev, R. Z.; Gavrilov, N. V.; Cholakh, S. O.

In: Physica Status Solidi (B) Basic Research, Vol. 252, No. 4, 01.01.2015, p. 748-754.

Research output: Contribution to journalArticlepeer-review

Harvard

Boukhvalov, DW, Korotin, DM, Efremov, AV, Kurmaev, EZ, Borchers, C, Zhidkov, IS, Gunderov, DV, Valiev, RZ, Gavrilov, NV & Cholakh, SO 2015, 'Modification of titanium and titanium dioxide surfaces by ion implantation: Combined XPS and DFT study', Physica Status Solidi (B) Basic Research, vol. 252, no. 4, pp. 748-754. https://doi.org/10.1002/pssb.201451362

APA

Boukhvalov, D. W., Korotin, D. M., Efremov, A. V., Kurmaev, E. Z., Borchers, C., Zhidkov, I. S., Gunderov, D. V., Valiev, R. Z., Gavrilov, N. V., & Cholakh, S. O. (2015). Modification of titanium and titanium dioxide surfaces by ion implantation: Combined XPS and DFT study. Physica Status Solidi (B) Basic Research, 252(4), 748-754. https://doi.org/10.1002/pssb.201451362

Vancouver

Boukhvalov DW, Korotin DM, Efremov AV, Kurmaev EZ, Borchers C, Zhidkov IS et al. Modification of titanium and titanium dioxide surfaces by ion implantation: Combined XPS and DFT study. Physica Status Solidi (B) Basic Research. 2015 Jan 1;252(4):748-754. https://doi.org/10.1002/pssb.201451362

Author

Boukhvalov, D. W. ; Korotin, D. M. ; Efremov, A. V. ; Kurmaev, E. Z. ; Borchers, C. ; Zhidkov, I. S. ; Gunderov, D. V. ; Valiev, R. Z. ; Gavrilov, N. V. ; Cholakh, S. O. / Modification of titanium and titanium dioxide surfaces by ion implantation : Combined XPS and DFT study. In: Physica Status Solidi (B) Basic Research. 2015 ; Vol. 252, No. 4. pp. 748-754.

BibTeX

@article{234511c4774d4d47bd384104bb1f1c72,
title = "Modification of titanium and titanium dioxide surfaces by ion implantation: Combined XPS and DFT study",
abstract = "The results of XPS measurements (core levels and valence bands) of P+, Ca+, P+Ca+ and Ca+P+ ion implanted (E=30 keV, D=1×1017cm-2) commercially pure titanium (cp-Ti) and first-principles density functional theory (DFT) calculations demonstrates formation of various structural defects in titanium dioxide films formed on the surface of implanted materials. We have found that for double implantation (Ti:P+,Ca+ and Ti:Ca+,P+) the outermost surface layer is formed mainly by Ca and P, respectively, i.e. the implantation sequence is very important. The DFT calculations show that under P+ and Ca+P+ ion implantation the formation energies for both cation (P-Ti) and anion (P-O) substitutions are comparable, which can induce the creation of [PO4]3- and Ti-P species. For Ca+ and P+Ca+ ion implantation the calculated formation energies correspond to Ca2+-Ti4+ cation substitution. This conclusion is in agreement with XPS Ca 2p and Ti 2p core levels and valence-band measurements and DFT calculations of the electronic structure of related compounds. The conversion of implanted ions to Ca2+ and [PO4]3- species provides a good biocompatibility of cp-Ti for further formation of hydroxyapatite.",
keywords = "DFT modelling, Ion implantation, Soft X-rays, Surface modification, Titanium, Titanium dioxide",
author = "Boukhvalov, {D. W.} and Korotin, {D. M.} and Efremov, {A. V.} and Kurmaev, {E. Z.} and C. Borchers and Zhidkov, {I. S.} and Gunderov, {D. V.} and Valiev, {R. Z.} and Gavrilov, {N. V.} and Cholakh, {S. O.}",
year = "2015",
month = jan,
day = "1",
doi = "10.1002/pssb.201451362",
language = "English",
volume = "252",
pages = "748--754",
journal = "Physica Status Solidi (B): Basic Research",
issn = "0370-1972",
publisher = "Wiley-Blackwell",
number = "4",

}

RIS

TY - JOUR

T1 - Modification of titanium and titanium dioxide surfaces by ion implantation

T2 - Combined XPS and DFT study

AU - Boukhvalov, D. W.

AU - Korotin, D. M.

AU - Efremov, A. V.

AU - Kurmaev, E. Z.

AU - Borchers, C.

AU - Zhidkov, I. S.

AU - Gunderov, D. V.

AU - Valiev, R. Z.

AU - Gavrilov, N. V.

AU - Cholakh, S. O.

PY - 2015/1/1

Y1 - 2015/1/1

N2 - The results of XPS measurements (core levels and valence bands) of P+, Ca+, P+Ca+ and Ca+P+ ion implanted (E=30 keV, D=1×1017cm-2) commercially pure titanium (cp-Ti) and first-principles density functional theory (DFT) calculations demonstrates formation of various structural defects in titanium dioxide films formed on the surface of implanted materials. We have found that for double implantation (Ti:P+,Ca+ and Ti:Ca+,P+) the outermost surface layer is formed mainly by Ca and P, respectively, i.e. the implantation sequence is very important. The DFT calculations show that under P+ and Ca+P+ ion implantation the formation energies for both cation (P-Ti) and anion (P-O) substitutions are comparable, which can induce the creation of [PO4]3- and Ti-P species. For Ca+ and P+Ca+ ion implantation the calculated formation energies correspond to Ca2+-Ti4+ cation substitution. This conclusion is in agreement with XPS Ca 2p and Ti 2p core levels and valence-band measurements and DFT calculations of the electronic structure of related compounds. The conversion of implanted ions to Ca2+ and [PO4]3- species provides a good biocompatibility of cp-Ti for further formation of hydroxyapatite.

AB - The results of XPS measurements (core levels and valence bands) of P+, Ca+, P+Ca+ and Ca+P+ ion implanted (E=30 keV, D=1×1017cm-2) commercially pure titanium (cp-Ti) and first-principles density functional theory (DFT) calculations demonstrates formation of various structural defects in titanium dioxide films formed on the surface of implanted materials. We have found that for double implantation (Ti:P+,Ca+ and Ti:Ca+,P+) the outermost surface layer is formed mainly by Ca and P, respectively, i.e. the implantation sequence is very important. The DFT calculations show that under P+ and Ca+P+ ion implantation the formation energies for both cation (P-Ti) and anion (P-O) substitutions are comparable, which can induce the creation of [PO4]3- and Ti-P species. For Ca+ and P+Ca+ ion implantation the calculated formation energies correspond to Ca2+-Ti4+ cation substitution. This conclusion is in agreement with XPS Ca 2p and Ti 2p core levels and valence-band measurements and DFT calculations of the electronic structure of related compounds. The conversion of implanted ions to Ca2+ and [PO4]3- species provides a good biocompatibility of cp-Ti for further formation of hydroxyapatite.

KW - DFT modelling

KW - Ion implantation

KW - Soft X-rays

KW - Surface modification

KW - Titanium

KW - Titanium dioxide

UR - http://www.scopus.com/inward/record.url?scp=84926524418&partnerID=8YFLogxK

U2 - 10.1002/pssb.201451362

DO - 10.1002/pssb.201451362

M3 - Article

AN - SCOPUS:84926524418

VL - 252

SP - 748

EP - 754

JO - Physica Status Solidi (B): Basic Research

JF - Physica Status Solidi (B): Basic Research

SN - 0370-1972

IS - 4

ER -

ID: 35167947