Standard
Measurement of the Neutron Lifetime with Ultracold Neutrons Stored in a Magneto-Gravitational Trap. / Ezhov, V. F.; Andreev, A. Z.; Ban, G.; Bazarov, B. A.; Geltenbort, P.; Glushkov, A. G.; Knyazkov, V. A.; Kovrizhnykh, N. A.; Krygin, G. B.; Naviliat-Cuncic, O.; Ryabov, V. L.
In:
JETP Letters, Vol. 107, No. 11, 01.06.2018, p. 671-675.
Research output: Contribution to journal › Article › peer-review
Harvard
Ezhov, VF, Andreev, AZ, Ban, G, Bazarov, BA, Geltenbort, P, Glushkov, AG, Knyazkov, VA
, Kovrizhnykh, NA, Krygin, GB, Naviliat-Cuncic, O & Ryabov, VL 2018, '
Measurement of the Neutron Lifetime with Ultracold Neutrons Stored in a Magneto-Gravitational Trap',
JETP Letters, vol. 107, no. 11, pp. 671-675.
https://doi.org/10.1134/S0021364018110024,
https://doi.org/10.1134/S0021364018110024
APA
Ezhov, V. F., Andreev, A. Z., Ban, G., Bazarov, B. A., Geltenbort, P., Glushkov, A. G., Knyazkov, V. A.
, Kovrizhnykh, N. A., Krygin, G. B., Naviliat-Cuncic, O., & Ryabov, V. L. (2018).
Measurement of the Neutron Lifetime with Ultracold Neutrons Stored in a Magneto-Gravitational Trap.
JETP Letters,
107(11), 671-675.
https://doi.org/10.1134/S0021364018110024,
https://doi.org/10.1134/S0021364018110024
Vancouver
Author
Ezhov, V. F. ; Andreev, A. Z. ; Ban, G. ; Bazarov, B. A. ; Geltenbort, P. ; Glushkov, A. G. ; Knyazkov, V. A.
; Kovrizhnykh, N. A. ; Krygin, G. B. ; Naviliat-Cuncic, O. ; Ryabov, V. L. /
Measurement of the Neutron Lifetime with Ultracold Neutrons Stored in a Magneto-Gravitational Trap. In:
JETP Letters. 2018 ; Vol. 107, No. 11. pp. 671-675.
BibTeX
@article{cd639230645941bd9e83f9461ffd7c02,
title = "Measurement of the Neutron Lifetime with Ultracold Neutrons Stored in a Magneto-Gravitational Trap",
abstract = "We report a measurement of the neutron lifetime using ultracold neutrons stored in a magneto-gravitational trap made of permanent magnets. Neutrons surviving in the trap after fixed storage times have been counted and the trap losses have continuously been monitored during storage by detecting neutrons leaking from the trap. The value of the neutron lifetime resulting from this measurement is τn = (878.3 ± 1.6stat ± 1.0syst) A unique feature of this experiment is the monitoring of leaking neutrons providing a robust control of the main systematic loss.",
author = "Ezhov, {V. F.} and Andreev, {A. Z.} and G. Ban and Bazarov, {B. A.} and P. Geltenbort and Glushkov, {A. G.} and Knyazkov, {V. A.} and Kovrizhnykh, {N. A.} and Krygin, {G. B.} and O. Naviliat-Cuncic and Ryabov, {V. L.}",
note = "Funding Information: We are indebted to T. Brenner for his assistance during the experiment. We thank F.J. Hartman, A. Mueller, S. Paul, R. Picker, A. Serebrov, and O. Zimmer for their contributions at an earlier stage of this project and E. Kats for useful discussions. This work was supported in part by the Russian Foundation for Basic Research (project no. 07-02-00077-a), by the French Ministry of Foreign Affairs (ECO-NET action 12649SH), and by the Agence Nationale de la Recherche (project BLANC06-3-136829 “Onelix”). Publisher Copyright: {\textcopyright} 2018, Pleiades Publishing, Inc. Copyright: Copyright 2018 Elsevier B.V., All rights reserved.",
year = "2018",
month = jun,
day = "1",
doi = "10.1134/S0021364018110024",
language = "English",
volume = "107",
pages = "671--675",
journal = "JETP Letters",
issn = "0021-3640",
publisher = "МАИК {"}Наука/Интерпериодика{"}",
number = "11",
}
RIS
TY - JOUR
T1 - Measurement of the Neutron Lifetime with Ultracold Neutrons Stored in a Magneto-Gravitational Trap
AU - Ezhov, V. F.
AU - Andreev, A. Z.
AU - Ban, G.
AU - Bazarov, B. A.
AU - Geltenbort, P.
AU - Glushkov, A. G.
AU - Knyazkov, V. A.
AU - Kovrizhnykh, N. A.
AU - Krygin, G. B.
AU - Naviliat-Cuncic, O.
AU - Ryabov, V. L.
N1 - Funding Information:
We are indebted to T. Brenner for his assistance during the experiment. We thank F.J. Hartman, A. Mueller, S. Paul, R. Picker, A. Serebrov, and O. Zimmer for their contributions at an earlier stage of this project and E. Kats for useful discussions. This work was supported in part by the Russian Foundation for Basic Research (project no. 07-02-00077-a), by the French Ministry of Foreign Affairs (ECO-NET action 12649SH), and by the Agence Nationale de la Recherche (project BLANC06-3-136829 “Onelix”).
Publisher Copyright:
© 2018, Pleiades Publishing, Inc.
Copyright:
Copyright 2018 Elsevier B.V., All rights reserved.
PY - 2018/6/1
Y1 - 2018/6/1
N2 - We report a measurement of the neutron lifetime using ultracold neutrons stored in a magneto-gravitational trap made of permanent magnets. Neutrons surviving in the trap after fixed storage times have been counted and the trap losses have continuously been monitored during storage by detecting neutrons leaking from the trap. The value of the neutron lifetime resulting from this measurement is τn = (878.3 ± 1.6stat ± 1.0syst) A unique feature of this experiment is the monitoring of leaking neutrons providing a robust control of the main systematic loss.
AB - We report a measurement of the neutron lifetime using ultracold neutrons stored in a magneto-gravitational trap made of permanent magnets. Neutrons surviving in the trap after fixed storage times have been counted and the trap losses have continuously been monitored during storage by detecting neutrons leaking from the trap. The value of the neutron lifetime resulting from this measurement is τn = (878.3 ± 1.6stat ± 1.0syst) A unique feature of this experiment is the monitoring of leaking neutrons providing a robust control of the main systematic loss.
UR - http://www.scopus.com/inward/record.url?scp=85047660435&partnerID=8YFLogxK
U2 - 10.1134/S0021364018110024
DO - 10.1134/S0021364018110024
M3 - Article
AN - SCOPUS:85047660435
VL - 107
SP - 671
EP - 675
JO - JETP Letters
JF - JETP Letters
SN - 0021-3640
IS - 11
ER -