Research output: Chapter in Book/Report/Conference proceeding › Article in an anthology › Research › peer-review
Mathematical Model for Myopia Correction with MyoRing Implants. / Корников, Владимир Васильевич; Бауэр, Светлана Михайловна; Венатовская, Людмила Александровна; Воронкова, Ева Боруховна; Авершина, Л.А. ; Терентьева, Анна Евгеньевна.
Progress in Continuum Mechanics. ed. / Holm Altenbach; Hans Irschik; Alexey V. Porubov. Vol. 196 Cham, Switzerland : Springer Nature, 2023. p. 81-90 (Advanced Structured Materials; Vol. 196).Research output: Chapter in Book/Report/Conference proceeding › Article in an anthology › Research › peer-review
}
TY - CHAP
T1 - Mathematical Model for Myopia Correction with MyoRing Implants
AU - Корников, Владимир Васильевич
AU - Бауэр, Светлана Михайловна
AU - Венатовская, Людмила Александровна
AU - Воронкова, Ева Боруховна
AU - Авершина, Л.А.
AU - Терентьева, Анна Евгеньевна
PY - 2023
Y1 - 2023
N2 - A finite-element simulation for the implantation of corneal rings for patients with high myopia is presented. The eyeball is modelled by joined spherical segments with different geometries and elastic properties. The ring implantation process is modelled by three surface-surface contact pairs: contact between corneal layers and contacts of the ring and with the lower and upper surface of the corneal pocket. The role of the surgical parameters (the MyoRing thickness and the implantation depth) on the stress-strain state is studied. The results of the simulation were compared with the clinical data on the change in curvature after the surgery.
AB - A finite-element simulation for the implantation of corneal rings for patients with high myopia is presented. The eyeball is modelled by joined spherical segments with different geometries and elastic properties. The ring implantation process is modelled by three surface-surface contact pairs: contact between corneal layers and contacts of the ring and with the lower and upper surface of the corneal pocket. The role of the surgical parameters (the MyoRing thickness and the implantation depth) on the stress-strain state is studied. The results of the simulation were compared with the clinical data on the change in curvature after the surgery.
UR - https://www.mendeley.com/catalogue/62c8380c-7eb9-3e5c-9a4b-39ffd0745391/
U2 - 10.1007/978-3-031-43736-6_6
DO - 10.1007/978-3-031-43736-6_6
M3 - Article in an anthology
VL - 196
T3 - Advanced Structured Materials
SP - 81
EP - 90
BT - Progress in Continuum Mechanics
A2 - Altenbach, Holm
A2 - Irschik, Hans
A2 - Porubov, Alexey V.
PB - Springer Nature
CY - Cham, Switzerland
ER -
ID: 111400378