Standard

Gas chromatographic identification of low-boiling organic solvents: evaluation of the information content of retention indices. / Зенкевич, Игорь Георгиевич.

In: Journal of Analytical Chemistry, Vol. 80, No. 11, 01.11.2025, p. 1945-1953.

Research output: Contribution to journalArticlepeer-review

Harvard

APA

Vancouver

Author

BibTeX

@article{4c5f0e54192b4986a6a5fd96932c3fb7,
title = "Gas chromatographic identification of low-boiling organic solvents: evaluation of the information content of retention indices",
abstract = "Abstract: The special features of gas chromatographic identification of low-boiling organic solvents based on their retention index values on standard nonpolar polydimethylsiloxane stationary phases was considered with the use of 80 most common organic solvents as an example. It was shown that one-dimensional analytical parameters, such as retention indices, cannot provide unambiguous identification of all compounds of this group because their informative value R(RI) in this group is only about 29, which is lower than the number of objects in the group. To solve the problem, it is necessary to supplement the chromatographic data with independent characteristics, and refractive indices () can be recommended as these characteristics because their determination requires minimal time and sample quantities. Nevertheless, about 10% of the solvents under consideration cannot be distinguished even based on the combinations of RI +. For comparison, the capabilities of using the dynamic viscosity of liquids as an additional analytical parameter were considered. The given table of retention indices for the most common organic solvents is of independent value for analytical practice.",
keywords = "В тексте публикации, additional analytical parameters, dynamic viscosity, gas chromatographic identification, insufficient information content, low-boiling organic solvents, refractive indices",
author = "Зенкевич, {Игорь Георгиевич}",
note = "Zenkevich I.G. // J. Analyt. Chem. 2025. V. 80. № 11. P. 1945-1953.",
year = "2025",
month = nov,
day = "1",
doi = "10.1134/S1061934825701084",
language = "English",
volume = "80",
pages = "1945--1953",
journal = "Journal of Analytical Chemistry",
issn = "1061-9348",
publisher = "МАИК {"}Наука/Интерпериодика{"}",
number = "11",

}

RIS

TY - JOUR

T1 - Gas chromatographic identification of low-boiling organic solvents: evaluation of the information content of retention indices

AU - Зенкевич, Игорь Георгиевич

N1 - Zenkevich I.G. // J. Analyt. Chem. 2025. V. 80. № 11. P. 1945-1953.

PY - 2025/11/1

Y1 - 2025/11/1

N2 - Abstract: The special features of gas chromatographic identification of low-boiling organic solvents based on their retention index values on standard nonpolar polydimethylsiloxane stationary phases was considered with the use of 80 most common organic solvents as an example. It was shown that one-dimensional analytical parameters, such as retention indices, cannot provide unambiguous identification of all compounds of this group because their informative value R(RI) in this group is only about 29, which is lower than the number of objects in the group. To solve the problem, it is necessary to supplement the chromatographic data with independent characteristics, and refractive indices () can be recommended as these characteristics because their determination requires minimal time and sample quantities. Nevertheless, about 10% of the solvents under consideration cannot be distinguished even based on the combinations of RI +. For comparison, the capabilities of using the dynamic viscosity of liquids as an additional analytical parameter were considered. The given table of retention indices for the most common organic solvents is of independent value for analytical practice.

AB - Abstract: The special features of gas chromatographic identification of low-boiling organic solvents based on their retention index values on standard nonpolar polydimethylsiloxane stationary phases was considered with the use of 80 most common organic solvents as an example. It was shown that one-dimensional analytical parameters, such as retention indices, cannot provide unambiguous identification of all compounds of this group because their informative value R(RI) in this group is only about 29, which is lower than the number of objects in the group. To solve the problem, it is necessary to supplement the chromatographic data with independent characteristics, and refractive indices () can be recommended as these characteristics because their determination requires minimal time and sample quantities. Nevertheless, about 10% of the solvents under consideration cannot be distinguished even based on the combinations of RI +. For comparison, the capabilities of using the dynamic viscosity of liquids as an additional analytical parameter were considered. The given table of retention indices for the most common organic solvents is of independent value for analytical practice.

KW - В тексте публикации

KW - additional analytical parameters

KW - dynamic viscosity

KW - gas chromatographic identification

KW - insufficient information content

KW - low-boiling organic solvents

KW - refractive indices

UR - https://www.mendeley.com/catalogue/01903f3e-71e6-37e7-8842-508d0f3b6126/

U2 - 10.1134/S1061934825701084

DO - 10.1134/S1061934825701084

M3 - Article

VL - 80

SP - 1945

EP - 1953

JO - Journal of Analytical Chemistry

JF - Journal of Analytical Chemistry

SN - 1061-9348

IS - 11

ER -

ID: 143010287