Research output: Contribution to journal › Article › peer-review
Flow analysis with chemiluminescence detection: Recent advances and applications. / Тимофеева, Ирина Игоревна; Вах, Кристина; Булатов, Андрей Васильевич; Worsfold, Paul.
In: Talanta, Vol. 179, 01.03.2018, p. 246-270.Research output: Contribution to journal › Article › peer-review
}
TY - JOUR
T1 - Flow analysis with chemiluminescence detection: Recent advances and applications
AU - Тимофеева, Ирина Игоревна
AU - Вах, Кристина
AU - Булатов, Андрей Васильевич
AU - Worsfold, Paul
N1 - Funding Information: The authors thank St. Petersburg State University (Grant no. 12.42.1462.2015 ), the Russian Foundation for Basic Research (Research projects no. 16-33-60137 mol_a_dk ), and the Russian Government (Project no. MD-6597.2016.3 ).
PY - 2018/3/1
Y1 - 2018/3/1
N2 - This article highlights the most important developments in flow analysis with chemiluminescence (CL) detection, describing different flow systems that are compatible with CL detection, detector designs, commonly applied CL reactions and approaches to sample treatment. Recent applications of flow analysis with CL detection (focusing on outputs published since 2010) are also presented. Applications are classified by sample matrix, covering foods and beverages, environmental matrices, pharmaceuticals and biological fluids. Comprehensive tables are provided for each area, listing the specific sample matrix, CL reaction used, linear range, limit of detection and sample treatment for each analyte. Finally, recent and emerging trends in the field are also discussed.
AB - This article highlights the most important developments in flow analysis with chemiluminescence (CL) detection, describing different flow systems that are compatible with CL detection, detector designs, commonly applied CL reactions and approaches to sample treatment. Recent applications of flow analysis with CL detection (focusing on outputs published since 2010) are also presented. Applications are classified by sample matrix, covering foods and beverages, environmental matrices, pharmaceuticals and biological fluids. Comprehensive tables are provided for each area, listing the specific sample matrix, CL reaction used, linear range, limit of detection and sample treatment for each analyte. Finally, recent and emerging trends in the field are also discussed.
KW - CL detection
KW - Environmental analysis
KW - Flow analysis
KW - Food analysis
KW - Pharmaceutical analysis
KW - Sample preparation
UR - http://www.scopus.com/inward/record.url?scp=85034089188&partnerID=8YFLogxK
U2 - 10.1016/j.talanta.2017.11.007
DO - 10.1016/j.talanta.2017.11.007
M3 - Article
VL - 179
SP - 246
EP - 270
JO - Talanta
JF - Talanta
SN - 0039-9140
ER -
ID: 33792788