Standard

Experimental Observation and Numerical Simulation of Spectra of Solid-Anode X-Ray Tubes. / Volkov, P. G.; Korobeinikov, S. I.; Nikolaev, V. I.; Sovkov, V. B.

In: Journal of Analytical Chemistry, Vol. 71, No. 5, 2016, p. 471-475.

Research output: Contribution to journalArticle

Harvard

Volkov, PG, Korobeinikov, SI, Nikolaev, VI & Sovkov, VB 2016, 'Experimental Observation and Numerical Simulation of Spectra of Solid-Anode X-Ray Tubes', Journal of Analytical Chemistry, vol. 71, no. 5, pp. 471-475. https://doi.org/10.1134/S1061934816030151

APA

Volkov, P. G., Korobeinikov, S. I., Nikolaev, V. I., & Sovkov, V. B. (2016). Experimental Observation and Numerical Simulation of Spectra of Solid-Anode X-Ray Tubes. Journal of Analytical Chemistry, 71(5), 471-475. https://doi.org/10.1134/S1061934816030151

Vancouver

Volkov PG, Korobeinikov SI, Nikolaev VI, Sovkov VB. Experimental Observation and Numerical Simulation of Spectra of Solid-Anode X-Ray Tubes. Journal of Analytical Chemistry. 2016;71(5):471-475. https://doi.org/10.1134/S1061934816030151

Author

Volkov, P. G. ; Korobeinikov, S. I. ; Nikolaev, V. I. ; Sovkov, V. B. / Experimental Observation and Numerical Simulation of Spectra of Solid-Anode X-Ray Tubes. In: Journal of Analytical Chemistry. 2016 ; Vol. 71, No. 5. pp. 471-475.

BibTeX

@article{d2ffa64a65bc416ea1d80c1b48843d54,
title = "Experimental Observation and Numerical Simulation of Spectra of Solid-Anode X-Ray Tubes",
abstract = "Possibilities of the experimental measurement and theoretical modeling of a fluorescence spectrum of a solid-anode X-ray tube are studied. A setup for the direct measurement of spectra of X-ray tubes of different types is created, spectra of a commercial BKh15 Svetlana X-ray tube are measured in wide range of anode voltages and currents. Calculations of spectra using the Ebel algorithm (Horst Ebel, 2006) with the parameters recommended in the original work ensure the satisfactory quality of the reproduction of the measured spectra, but demonstrate some statistically noticeable deviations. The optimization of model parameters ensures the improvement of the quality of simulation.",
keywords = "X-ray fluorescence spectra, elemental analysis of substances",
author = "Volkov, {P. G.} and Korobeinikov, {S. I.} and Nikolaev, {V. I.} and Sovkov, {V. B.}",
note = "Volkov, P.G., Korobeinikov, S.I., Nikolaev, V.I. et al. Experimental observation and numerical simulation of spectra of solid-anode X-ray tubes. J Anal Chem 71, 471–475 (2016). https://doi.org/10.1134/S1061934816030151",
year = "2016",
doi = "10.1134/S1061934816030151",
language = "English",
volume = "71",
pages = "471--475",
journal = "Journal of Analytical Chemistry",
issn = "1061-9348",
publisher = "МАИК {"}Наука/Интерпериодика{"}",
number = "5",

}

RIS

TY - JOUR

T1 - Experimental Observation and Numerical Simulation of Spectra of Solid-Anode X-Ray Tubes

AU - Volkov, P. G.

AU - Korobeinikov, S. I.

AU - Nikolaev, V. I.

AU - Sovkov, V. B.

N1 - Volkov, P.G., Korobeinikov, S.I., Nikolaev, V.I. et al. Experimental observation and numerical simulation of spectra of solid-anode X-ray tubes. J Anal Chem 71, 471–475 (2016). https://doi.org/10.1134/S1061934816030151

PY - 2016

Y1 - 2016

N2 - Possibilities of the experimental measurement and theoretical modeling of a fluorescence spectrum of a solid-anode X-ray tube are studied. A setup for the direct measurement of spectra of X-ray tubes of different types is created, spectra of a commercial BKh15 Svetlana X-ray tube are measured in wide range of anode voltages and currents. Calculations of spectra using the Ebel algorithm (Horst Ebel, 2006) with the parameters recommended in the original work ensure the satisfactory quality of the reproduction of the measured spectra, but demonstrate some statistically noticeable deviations. The optimization of model parameters ensures the improvement of the quality of simulation.

AB - Possibilities of the experimental measurement and theoretical modeling of a fluorescence spectrum of a solid-anode X-ray tube are studied. A setup for the direct measurement of spectra of X-ray tubes of different types is created, spectra of a commercial BKh15 Svetlana X-ray tube are measured in wide range of anode voltages and currents. Calculations of spectra using the Ebel algorithm (Horst Ebel, 2006) with the parameters recommended in the original work ensure the satisfactory quality of the reproduction of the measured spectra, but demonstrate some statistically noticeable deviations. The optimization of model parameters ensures the improvement of the quality of simulation.

KW - X-ray fluorescence spectra

KW - elemental analysis of substances

UR - https://www.elibrary.ru/item.asp?id=27159020

U2 - 10.1134/S1061934816030151

DO - 10.1134/S1061934816030151

M3 - Article

VL - 71

SP - 471

EP - 475

JO - Journal of Analytical Chemistry

JF - Journal of Analytical Chemistry

SN - 1061-9348

IS - 5

ER -

ID: 7558268