Standard

Experience of highly sensitive troponin i determining in practice of cardiac department of multidisciplinary hospital. / Pushkin, A. S.; Yakovlev, A. A.; Rukavishnikova, S. A.; Akhmedov, T. A.; Garakhanyan, A. A.

In: Kardiologiya i Serdechno-Sosudistaya Khirurgiya, Vol. 8, No. 6, 2015, p. 51-57.

Research output: Contribution to journalArticlepeer-review

Harvard

Pushkin, AS, Yakovlev, AA, Rukavishnikova, SA, Akhmedov, TA & Garakhanyan, AA 2015, 'Experience of highly sensitive troponin i determining in practice of cardiac department of multidisciplinary hospital', Kardiologiya i Serdechno-Sosudistaya Khirurgiya, vol. 8, no. 6, pp. 51-57. https://doi.org/10.17116/kardio20158651-57

APA

Pushkin, A. S., Yakovlev, A. A., Rukavishnikova, S. A., Akhmedov, T. A., & Garakhanyan, A. A. (2015). Experience of highly sensitive troponin i determining in practice of cardiac department of multidisciplinary hospital. Kardiologiya i Serdechno-Sosudistaya Khirurgiya, 8(6), 51-57. https://doi.org/10.17116/kardio20158651-57

Vancouver

Pushkin AS, Yakovlev AA, Rukavishnikova SA, Akhmedov TA, Garakhanyan AA. Experience of highly sensitive troponin i determining in practice of cardiac department of multidisciplinary hospital. Kardiologiya i Serdechno-Sosudistaya Khirurgiya. 2015;8(6):51-57. https://doi.org/10.17116/kardio20158651-57

Author

Pushkin, A. S. ; Yakovlev, A. A. ; Rukavishnikova, S. A. ; Akhmedov, T. A. ; Garakhanyan, A. A. / Experience of highly sensitive troponin i determining in practice of cardiac department of multidisciplinary hospital. In: Kardiologiya i Serdechno-Sosudistaya Khirurgiya. 2015 ; Vol. 8, No. 6. pp. 51-57.

BibTeX

@article{40a6894c519e4d99b04c0312b1b69746,
title = "Experience of highly sensitive troponin i determining in practice of cardiac department of multidisciplinary hospital",
abstract = "It was compared method of highly sensitive troponin I determination that was introduced into cardiac center practice with other previously applied techniques. The study was conducted using chemiluminescent immunoassay on ChemiFlex microcorpuscles. Two quantitative methods of troponin I level measurement were compared namely ARCHITEST STAT Troponin I and ARCHITEST STAT high sensitive Troponin I («Abbott»). It was shown that the use of test for highly sensitive troponin I (ARCHITEST STAT high sensitive Troponin I) increased number of patients with acute coronary syndrome who underwent invasive treatment and those who needed for medical assistance in target time period. It was concluded that ARCHITEST STAT high sensitive Troponin I technique has higher sensitivity, specificity and diagnostic value of both positive and negative results. Also use of reduced diagnostic threshold for myocardial necrosis increases myocardial infarction detection rate.",
keywords = "Acute coronary syndrome, Acute myocardial infarction, Chemiluminescent immunoassay, Highly sensitive troponin I",
author = "Pushkin, {A. S.} and Yakovlev, {A. A.} and Rukavishnikova, {S. A.} and Akhmedov, {T. A.} and Garakhanyan, {A. A.}",
note = "Publisher Copyright: {\textcopyright} 2015, Media Sphera Publishing Group. All rights reserved.",
year = "2015",
doi = "10.17116/kardio20158651-57",
language = "English",
volume = "8",
pages = "51--57",
journal = "КАРДИОЛОГИЯ И СЕРДЕЧНО-СОСУДИСТАЯ ХИРУРГИЯ",
issn = "1996-6385",
publisher = "Медиа Сфера",
number = "6",

}

RIS

TY - JOUR

T1 - Experience of highly sensitive troponin i determining in practice of cardiac department of multidisciplinary hospital

AU - Pushkin, A. S.

AU - Yakovlev, A. A.

AU - Rukavishnikova, S. A.

AU - Akhmedov, T. A.

AU - Garakhanyan, A. A.

N1 - Publisher Copyright: © 2015, Media Sphera Publishing Group. All rights reserved.

PY - 2015

Y1 - 2015

N2 - It was compared method of highly sensitive troponin I determination that was introduced into cardiac center practice with other previously applied techniques. The study was conducted using chemiluminescent immunoassay on ChemiFlex microcorpuscles. Two quantitative methods of troponin I level measurement were compared namely ARCHITEST STAT Troponin I and ARCHITEST STAT high sensitive Troponin I («Abbott»). It was shown that the use of test for highly sensitive troponin I (ARCHITEST STAT high sensitive Troponin I) increased number of patients with acute coronary syndrome who underwent invasive treatment and those who needed for medical assistance in target time period. It was concluded that ARCHITEST STAT high sensitive Troponin I technique has higher sensitivity, specificity and diagnostic value of both positive and negative results. Also use of reduced diagnostic threshold for myocardial necrosis increases myocardial infarction detection rate.

AB - It was compared method of highly sensitive troponin I determination that was introduced into cardiac center practice with other previously applied techniques. The study was conducted using chemiluminescent immunoassay on ChemiFlex microcorpuscles. Two quantitative methods of troponin I level measurement were compared namely ARCHITEST STAT Troponin I and ARCHITEST STAT high sensitive Troponin I («Abbott»). It was shown that the use of test for highly sensitive troponin I (ARCHITEST STAT high sensitive Troponin I) increased number of patients with acute coronary syndrome who underwent invasive treatment and those who needed for medical assistance in target time period. It was concluded that ARCHITEST STAT high sensitive Troponin I technique has higher sensitivity, specificity and diagnostic value of both positive and negative results. Also use of reduced diagnostic threshold for myocardial necrosis increases myocardial infarction detection rate.

KW - Acute coronary syndrome

KW - Acute myocardial infarction

KW - Chemiluminescent immunoassay

KW - Highly sensitive troponin I

UR - http://www.scopus.com/inward/record.url?scp=85115113484&partnerID=8YFLogxK

U2 - 10.17116/kardio20158651-57

DO - 10.17116/kardio20158651-57

M3 - Article

AN - SCOPUS:85115113484

VL - 8

SP - 51

EP - 57

JO - КАРДИОЛОГИЯ И СЕРДЕЧНО-СОСУДИСТАЯ ХИРУРГИЯ

JF - КАРДИОЛОГИЯ И СЕРДЕЧНО-СОСУДИСТАЯ ХИРУРГИЯ

SN - 1996-6385

IS - 6

ER -

ID: 87761459