@article{0d4071b7b926419193d8eb3d0c35fc6b,
title = "Evaluation of the Influence of the Beam Pipe on the Accuracy of Solving the Problem of Determining the Coordinates of Au–Au Interactions",
abstract = "The problem of determining the coordinates of Au–Au interactions at a center-of-mass energy of 7 GeV and the influence of different ion beam pipe configurations on the results are considered. The modeling was performed using the UrQMD 3.4 event generator, Geant4, and a neural network model. Eight configurations were studied: ion beam pipes with wall thicknesses of 1.2, 3, 5, and 8 mm, with the wall material being carbon and iron. The use of beam pipe with walls with thicknesses of 1–3 mm does not significantly affect the outcome, but further increasing the wall thickness significantly reduces accuracy.",
author = "Жаров, {Михаил Андреевич} and Размыслов, {Константин Владимирович} and Валиев, {Фархат Фагимович} and Монахов, {Вадим Валериевич}",
year = "2025",
month = may,
day = "31",
doi = "10.1134/s1063778825700334",
language = "English",
volume = "88",
pages = "302--305",
journal = "Physics of Atomic Nuclei",
issn = "1063-7788",
publisher = "МАИК {"}Наука/Интерпериодика{"}",
number = "2",

}

RIS

TY - JOUR

T1 - Evaluation of the Influence of the Beam Pipe on the Accuracy of Solving the Problem of Determining the Coordinates of Au–Au Interactions

AU - Жаров, Михаил Андреевич

AU - Размыслов, Константин Владимирович

AU - Валиев, Фархат Фагимович

AU - Монахов, Вадим Валериевич

PY - 2025/5/31

Y1 - 2025/5/31

N2 - The problem of determining the coordinates of Au–Au interactions at a center-of-mass energy of 7 GeV and the influence of different ion beam pipe configurations on the results are considered. The modeling was performed using the UrQMD 3.4 event generator, Geant4, and a neural network model. Eight configurations were studied: ion beam pipes with wall thicknesses of 1.2, 3, 5, and 8 mm, with the wall material being carbon and iron. The use of beam pipe with walls with thicknesses of 1–3 mm does not significantly affect the outcome, but further increasing the wall thickness significantly reduces accuracy.

AB - The problem of determining the coordinates of Au–Au interactions at a center-of-mass energy of 7 GeV and the influence of different ion beam pipe configurations on the results are considered. The modeling was performed using the UrQMD 3.4 event generator, Geant4, and a neural network model. Eight configurations were studied: ion beam pipes with wall thicknesses of 1.2, 3, 5, and 8 mm, with the wall material being carbon and iron. The use of beam pipe with walls with thicknesses of 1–3 mm does not significantly affect the outcome, but further increasing the wall thickness significantly reduces accuracy.

UR - https://www.mendeley.com/catalogue/ffbbc4eb-128d-39c3-aa75-60c335afb970/

U2 - 10.1134/s1063778825700334

DO - 10.1134/s1063778825700334

M3 - Article

VL - 88

SP - 302

EP - 305

JO - Physics of Atomic Nuclei

JF - Physics of Atomic Nuclei

SN - 1063-7788

IS - 2

ER -