Standard

EFATOM two-detector one-photon emission gamma tomograph. / Arlychev, M. A.; Novikov, V. L.; Sidorov, A. V.; Fialkovskiǐ, A. M.; Kotina, E. D.; Ovsyannikov, D. A.; Ploskikh, V. A.

In: Technical Physics, Vol. 54, No. 10, 01.10.2009, p. 1539-1547.

Research output: Contribution to journalArticlepeer-review

Harvard

Arlychev, MA, Novikov, VL, Sidorov, AV, Fialkovskiǐ, AM, Kotina, ED, Ovsyannikov, DA & Ploskikh, VA 2009, 'EFATOM two-detector one-photon emission gamma tomograph', Technical Physics, vol. 54, no. 10, pp. 1539-1547. https://doi.org/10.1134/S106378420910020X

APA

Vancouver

Arlychev MA, Novikov VL, Sidorov AV, Fialkovskiǐ AM, Kotina ED, Ovsyannikov DA et al. EFATOM two-detector one-photon emission gamma tomograph. Technical Physics. 2009 Oct 1;54(10):1539-1547. https://doi.org/10.1134/S106378420910020X

Author

Arlychev, M. A. ; Novikov, V. L. ; Sidorov, A. V. ; Fialkovskiǐ, A. M. ; Kotina, E. D. ; Ovsyannikov, D. A. ; Ploskikh, V. A. / EFATOM two-detector one-photon emission gamma tomograph. In: Technical Physics. 2009 ; Vol. 54, No. 10. pp. 1539-1547.

BibTeX

@article{d9d541c1a7fd4747bac140b7add22fbb,
title = "EFATOM two-detector one-photon emission gamma tomograph",
abstract = "The EFATOM two-detector one-photon emission computer tomograph, which is intended for radionuclide diagnostics of the internal organs and systems in the human body, has been designed and tested. A schematic diagram of its software package and detection units is represented. The results of its technical tests are presented. The characteristics of the EFATOM gamma tomograph are compared with its foreign analogs.",
author = "Arlychev, {M. A.} and Novikov, {V. L.} and Sidorov, {A. V.} and Fialkovskiǐ, {A. M.} and Kotina, {E. D.} and Ovsyannikov, {D. A.} and Ploskikh, {V. A.}",
year = "2009",
month = oct,
day = "1",
doi = "10.1134/S106378420910020X",
language = "English",
volume = "54",
pages = "1539--1547",
journal = "Technical Physics",
issn = "1063-7842",
publisher = "Pleiades Publishing",
number = "10",

}

RIS

TY - JOUR

T1 - EFATOM two-detector one-photon emission gamma tomograph

AU - Arlychev, M. A.

AU - Novikov, V. L.

AU - Sidorov, A. V.

AU - Fialkovskiǐ, A. M.

AU - Kotina, E. D.

AU - Ovsyannikov, D. A.

AU - Ploskikh, V. A.

PY - 2009/10/1

Y1 - 2009/10/1

N2 - The EFATOM two-detector one-photon emission computer tomograph, which is intended for radionuclide diagnostics of the internal organs and systems in the human body, has been designed and tested. A schematic diagram of its software package and detection units is represented. The results of its technical tests are presented. The characteristics of the EFATOM gamma tomograph are compared with its foreign analogs.

AB - The EFATOM two-detector one-photon emission computer tomograph, which is intended for radionuclide diagnostics of the internal organs and systems in the human body, has been designed and tested. A schematic diagram of its software package and detection units is represented. The results of its technical tests are presented. The characteristics of the EFATOM gamma tomograph are compared with its foreign analogs.