Research output: Chapter in Book/Report/Conference proceeding › Conference contribution › Research › peer-review
Accuracy of applanation tonometry readings before and after refractive surgery. / Bauer, S. M.; Venatovskaya, L.; Voronkova, E.
Shell Structures: Theory and Applications Volume 4 - Proceedings of the 11th International Conference on Shell Structures: Theory and Applications, SSTA 2017. ed. / Wojciech Pietraszkiewicz; Wojciech Witkowski. Vol. 4 Taylor & Francis, 2018. p. 495-498 (Shell Structures: Theory and Applications Volume 4 - Proceedings of the 11th International Conference on Shell Structures: Theory and Applications, SSTA 2017).Research output: Chapter in Book/Report/Conference proceeding › Conference contribution › Research › peer-review
}
TY - GEN
T1 - Accuracy of applanation tonometry readings before and after refractive surgery
AU - Bauer, S. M.
AU - Venatovskaya, L.
AU - Voronkova, E.
N1 - Conference code: 11
PY - 2018/1/1
Y1 - 2018/1/1
N2 - The accuracy of applanation tonometry readings before and after hyperopia correction surgery is discussed. The elastic system cornea-sclera is presented as two conjugate transversely isotropic spherical segments loaded with internal pressure in the finite element software ANSYS, Inc. The cornea is simulated as multi-layered transversely isotropic elastic shell and the sclera is modelled by a transversely isotropic homogeneous elastic shell. In order to estimate changes in the intraocular pressure readings obtained by Goldmann and Maklakoff applanation tonometers after hyperopia surgery the problem of deformation of the cornea under the load with a flat base is considered. The intraocular pressure readings before and after the surgeries for two types of tonometers are compared for the same value of true intraocular pressure.
AB - The accuracy of applanation tonometry readings before and after hyperopia correction surgery is discussed. The elastic system cornea-sclera is presented as two conjugate transversely isotropic spherical segments loaded with internal pressure in the finite element software ANSYS, Inc. The cornea is simulated as multi-layered transversely isotropic elastic shell and the sclera is modelled by a transversely isotropic homogeneous elastic shell. In order to estimate changes in the intraocular pressure readings obtained by Goldmann and Maklakoff applanation tonometers after hyperopia surgery the problem of deformation of the cornea under the load with a flat base is considered. The intraocular pressure readings before and after the surgeries for two types of tonometers are compared for the same value of true intraocular pressure.
UR - http://www.scopus.com/inward/record.url?scp=85063860801&partnerID=8YFLogxK
U2 - 10.1201/9781315166605-114
DO - 10.1201/9781315166605-114
M3 - Conference contribution
AN - SCOPUS:85063860801
SN - 9781138050457
VL - 4
T3 - Shell Structures: Theory and Applications Volume 4 - Proceedings of the 11th International Conference on Shell Structures: Theory and Applications, SSTA 2017
SP - 495
EP - 498
BT - Shell Structures
A2 - Pietraszkiewicz, Wojciech
A2 - Witkowski, Wojciech
PB - Taylor & Francis
T2 - 11th International Conference "Shell Structures: Theory and Applications"
Y2 - 11 October 2017 through 13 October 2017
ER -
ID: 9179938