Standard

Accuracy of applanation tonometry readings before and after refractive surgery. / Bauer, S. M.; Venatovskaya, L.; Voronkova, E.

Shell Structures: Theory and Applications Volume 4 - Proceedings of the 11th International Conference on Shell Structures: Theory and Applications, SSTA 2017. ed. / Wojciech Pietraszkiewicz; Wojciech Witkowski. Vol. 4 Taylor & Francis, 2018. p. 495-498 (Shell Structures: Theory and Applications Volume 4 - Proceedings of the 11th International Conference on Shell Structures: Theory and Applications, SSTA 2017).

Research output: Chapter in Book/Report/Conference proceedingConference contributionResearchpeer-review

Harvard

Bauer, SM, Venatovskaya, L & Voronkova, E 2018, Accuracy of applanation tonometry readings before and after refractive surgery. in W Pietraszkiewicz & W Witkowski (eds), Shell Structures: Theory and Applications Volume 4 - Proceedings of the 11th International Conference on Shell Structures: Theory and Applications, SSTA 2017. vol. 4, Shell Structures: Theory and Applications Volume 4 - Proceedings of the 11th International Conference on Shell Structures: Theory and Applications, SSTA 2017, Taylor & Francis, pp. 495-498, 11th International Conference "Shell Structures: Theory and Applications", Gdansk, Poland, 11/10/17. https://doi.org/10.1201/9781315166605-114

APA

Bauer, S. M., Venatovskaya, L., & Voronkova, E. (2018). Accuracy of applanation tonometry readings before and after refractive surgery. In W. Pietraszkiewicz, & W. Witkowski (Eds.), Shell Structures: Theory and Applications Volume 4 - Proceedings of the 11th International Conference on Shell Structures: Theory and Applications, SSTA 2017 (Vol. 4, pp. 495-498). (Shell Structures: Theory and Applications Volume 4 - Proceedings of the 11th International Conference on Shell Structures: Theory and Applications, SSTA 2017). Taylor & Francis. https://doi.org/10.1201/9781315166605-114

Vancouver

Bauer SM, Venatovskaya L, Voronkova E. Accuracy of applanation tonometry readings before and after refractive surgery. In Pietraszkiewicz W, Witkowski W, editors, Shell Structures: Theory and Applications Volume 4 - Proceedings of the 11th International Conference on Shell Structures: Theory and Applications, SSTA 2017. Vol. 4. Taylor & Francis. 2018. p. 495-498. (Shell Structures: Theory and Applications Volume 4 - Proceedings of the 11th International Conference on Shell Structures: Theory and Applications, SSTA 2017). https://doi.org/10.1201/9781315166605-114

Author

Bauer, S. M. ; Venatovskaya, L. ; Voronkova, E. / Accuracy of applanation tonometry readings before and after refractive surgery. Shell Structures: Theory and Applications Volume 4 - Proceedings of the 11th International Conference on Shell Structures: Theory and Applications, SSTA 2017. editor / Wojciech Pietraszkiewicz ; Wojciech Witkowski. Vol. 4 Taylor & Francis, 2018. pp. 495-498 (Shell Structures: Theory and Applications Volume 4 - Proceedings of the 11th International Conference on Shell Structures: Theory and Applications, SSTA 2017).

BibTeX

@inproceedings{9d53562d1fd94247a31e9dbb2819c449,
title = "Accuracy of applanation tonometry readings before and after refractive surgery",
abstract = "The accuracy of applanation tonometry readings before and after hyperopia correction surgery is discussed. The elastic system cornea-sclera is presented as two conjugate transversely isotropic spherical segments loaded with internal pressure in the finite element software ANSYS, Inc. The cornea is simulated as multi-layered transversely isotropic elastic shell and the sclera is modelled by a transversely isotropic homogeneous elastic shell. In order to estimate changes in the intraocular pressure readings obtained by Goldmann and Maklakoff applanation tonometers after hyperopia surgery the problem of deformation of the cornea under the load with a flat base is considered. The intraocular pressure readings before and after the surgeries for two types of tonometers are compared for the same value of true intraocular pressure.",
author = "Bauer, {S. M.} and L. Venatovskaya and E. Voronkova",
note = "Shell Structures: Theory and Applications, Volume 4, Proceedings of the 11 th SSTA conference, Gdansk, Poland, 11-13 October 2017; 11th International Conference {"}Shell Structures: Theory and Applications{"} ; Conference date: 11-10-2017 Through 13-10-2017",
year = "2018",
month = jan,
day = "1",
doi = "10.1201/9781315166605-114",
language = "English",
isbn = "9781138050457",
volume = "4",
series = "Shell Structures: Theory and Applications Volume 4 - Proceedings of the 11th International Conference on Shell Structures: Theory and Applications, SSTA 2017",
publisher = "Taylor & Francis",
pages = "495--498",
editor = "Wojciech Pietraszkiewicz and Wojciech Witkowski",
booktitle = "Shell Structures",
address = "United Kingdom",
url = "https://wilis.pg.edu.pl/ssta/welcome",

}

RIS

TY - GEN

T1 - Accuracy of applanation tonometry readings before and after refractive surgery

AU - Bauer, S. M.

AU - Venatovskaya, L.

AU - Voronkova, E.

N1 - Conference code: 11

PY - 2018/1/1

Y1 - 2018/1/1

N2 - The accuracy of applanation tonometry readings before and after hyperopia correction surgery is discussed. The elastic system cornea-sclera is presented as two conjugate transversely isotropic spherical segments loaded with internal pressure in the finite element software ANSYS, Inc. The cornea is simulated as multi-layered transversely isotropic elastic shell and the sclera is modelled by a transversely isotropic homogeneous elastic shell. In order to estimate changes in the intraocular pressure readings obtained by Goldmann and Maklakoff applanation tonometers after hyperopia surgery the problem of deformation of the cornea under the load with a flat base is considered. The intraocular pressure readings before and after the surgeries for two types of tonometers are compared for the same value of true intraocular pressure.

AB - The accuracy of applanation tonometry readings before and after hyperopia correction surgery is discussed. The elastic system cornea-sclera is presented as two conjugate transversely isotropic spherical segments loaded with internal pressure in the finite element software ANSYS, Inc. The cornea is simulated as multi-layered transversely isotropic elastic shell and the sclera is modelled by a transversely isotropic homogeneous elastic shell. In order to estimate changes in the intraocular pressure readings obtained by Goldmann and Maklakoff applanation tonometers after hyperopia surgery the problem of deformation of the cornea under the load with a flat base is considered. The intraocular pressure readings before and after the surgeries for two types of tonometers are compared for the same value of true intraocular pressure.

UR - http://www.scopus.com/inward/record.url?scp=85063860801&partnerID=8YFLogxK

U2 - 10.1201/9781315166605-114

DO - 10.1201/9781315166605-114

M3 - Conference contribution

AN - SCOPUS:85063860801

SN - 9781138050457

VL - 4

T3 - Shell Structures: Theory and Applications Volume 4 - Proceedings of the 11th International Conference on Shell Structures: Theory and Applications, SSTA 2017

SP - 495

EP - 498

BT - Shell Structures

A2 - Pietraszkiewicz, Wojciech

A2 - Witkowski, Wojciech

PB - Taylor & Francis

T2 - 11th International Conference "Shell Structures: Theory and Applications"

Y2 - 11 October 2017 through 13 October 2017

ER -

ID: 9179938