Numerical study of heating the gas in an atmospheric pressure cold plasma generator

V. Bekasov, G. Kirsanov, S. Eliseev, A. Kudryavtsev, S. Sysoev, A. Saifutdinov

Результат исследований: Научные публикации в периодических изданияхстатья

Выдержка

We report the results of two-dimensional, axisymmetric numerical simulation of a cold plasma generator for medical applications. Helium is considered as a working gas, a large number of plasma- chemical reactions are taken into account. We carried out numerical experiments on a cold atmospheric plasma under different external conditions. Spatial distribution of the neutral gas temperature and its dependence on the discharge current has been obtained. The numerical results point to a wide range of applications of such plasma generators in medicine.

Язык оригиналаанглийский
Страницы (с-по)155-163
Число страниц9
ЖурналHigh Temperature Material Processes
Том18
Номер выпуска3
DOI
СостояниеОпубликовано - 2014
Опубликовано для внешнего пользованияДа

Отпечаток

Plasma Gases
plasma generators
cold plasmas
Atmospheric pressure
atmospheric pressure
Gases
Plasmas
Heating
heating
neutral gases
gas temperature
medicine
gases
chemical reactions
Helium
spatial distribution
helium
Medical applications
temperature dependence
Spatial distribution

Предметные области Scopus

  • Физика конденсатов
  • Технология (все)
  • Материаловедение (все)
  • Энергетическая технология
  • Спектроскопия
  • Физическая и теоретическая химия

Цитировать

Bekasov, V. ; Kirsanov, G. ; Eliseev, S. ; Kudryavtsev, A. ; Sysoev, S. ; Saifutdinov, A. / Numerical study of heating the gas in an atmospheric pressure cold plasma generator. В: High Temperature Material Processes. 2014 ; Том 18, № 3. стр. 155-163.
@article{478aef767075489cb538464e6b231746,
title = "Numerical study of heating the gas in an atmospheric pressure cold plasma generator",
abstract = "We report the results of two-dimensional, axisymmetric numerical simulation of a cold plasma generator for medical applications. Helium is considered as a working gas, a large number of plasma- chemical reactions are taken into account. We carried out numerical experiments on a cold atmospheric plasma under different external conditions. Spatial distribution of the neutral gas temperature and its dependence on the discharge current has been obtained. The numerical results point to a wide range of applications of such plasma generators in medicine.",
keywords = "Cold plasma generator, Medical plasma applications, Numerical simulation",
author = "V. Bekasov and G. Kirsanov and S. Eliseev and A. Kudryavtsev and S. Sysoev and A. Saifutdinov",
year = "2014",
doi = "10.1615/HighTempMatProc.2015015449",
language = "English",
volume = "18",
pages = "155--163",
journal = "High Temperature Material Processes",
issn = "1093-3611",
publisher = "Begell House Inc.",
number = "3",

}

Numerical study of heating the gas in an atmospheric pressure cold plasma generator. / Bekasov, V.; Kirsanov, G.; Eliseev, S.; Kudryavtsev, A.; Sysoev, S.; Saifutdinov, A.

В: High Temperature Material Processes, Том 18, № 3, 2014, стр. 155-163.

Результат исследований: Научные публикации в периодических изданияхстатья

TY - JOUR

T1 - Numerical study of heating the gas in an atmospheric pressure cold plasma generator

AU - Bekasov, V.

AU - Kirsanov, G.

AU - Eliseev, S.

AU - Kudryavtsev, A.

AU - Sysoev, S.

AU - Saifutdinov, A.

PY - 2014

Y1 - 2014

N2 - We report the results of two-dimensional, axisymmetric numerical simulation of a cold plasma generator for medical applications. Helium is considered as a working gas, a large number of plasma- chemical reactions are taken into account. We carried out numerical experiments on a cold atmospheric plasma under different external conditions. Spatial distribution of the neutral gas temperature and its dependence on the discharge current has been obtained. The numerical results point to a wide range of applications of such plasma generators in medicine.

AB - We report the results of two-dimensional, axisymmetric numerical simulation of a cold plasma generator for medical applications. Helium is considered as a working gas, a large number of plasma- chemical reactions are taken into account. We carried out numerical experiments on a cold atmospheric plasma under different external conditions. Spatial distribution of the neutral gas temperature and its dependence on the discharge current has been obtained. The numerical results point to a wide range of applications of such plasma generators in medicine.

KW - Cold plasma generator

KW - Medical plasma applications

KW - Numerical simulation

UR - http://www.scopus.com/inward/record.url?scp=84955314565&partnerID=8YFLogxK

U2 - 10.1615/HighTempMatProc.2015015449

DO - 10.1615/HighTempMatProc.2015015449

M3 - Article

AN - SCOPUS:84955314565

VL - 18

SP - 155

EP - 163

JO - High Temperature Material Processes

JF - High Temperature Material Processes

SN - 1093-3611

IS - 3

ER -