Measurement of Zernike mode amplitude by the wavefront sensor, based on the Fourier-hologram of the diffuse scattered mode

V. V. Orlov, V. Yu Venediktov, A. V. Gorelaya, E. V. Shubenkova, D. Z. Zhamalatdinov

Результат исследований: Научные публикации в периодических изданияхстатья

1 цитирование (Scopus)

Выдержка

First experimental demonstration of the device, providing measurement of Zernike polynomial in the incoming wavefront by the use of the Fourier-hologram, recorded with the use of diffuse scattered beam. Signal to noise ratio of such approach was investigated. The principle of the sensor design can significantly increase the intensity of the waves, reconstructed by the holograms of the sensor. The intensity distribution of the reconstructed waves is an Airy picture that changes only in intensity, which eliminates the errors of intensity measurements caused by the influence of aberrations.

Язык оригиналаанглийский
Страницы (с-по)214-218
Число страниц5
ЖурналOptics and Laser Technology
Том116
DOI
СостояниеОпубликовано - 1 авг 2019

Отпечаток

Holograms
Wavefronts
Laser modes
sensors
Sensors
Aberrations
Signal to noise ratio
Demonstrations
Polynomials
aberration
polynomials
signal to noise ratios

Предметные области Scopus

  • Электроника, оптика и магнитные материалы
  • Атомная и молекулярная физика и оптика
  • Электротехника и электроника

Цитировать

Orlov, V. V. ; Venediktov, V. Yu ; Gorelaya, A. V. ; Shubenkova, E. V. ; Zhamalatdinov, D. Z. / Measurement of Zernike mode amplitude by the wavefront sensor, based on the Fourier-hologram of the diffuse scattered mode. В: Optics and Laser Technology. 2019 ; Том 116. стр. 214-218.
@article{a4bb747d5cd949d5b7bb72aa76bc2e47,
title = "Measurement of Zernike mode amplitude by the wavefront sensor, based on the Fourier-hologram of the diffuse scattered mode",
abstract = "First experimental demonstration of the device, providing measurement of Zernike polynomial in the incoming wavefront by the use of the Fourier-hologram, recorded with the use of diffuse scattered beam. Signal to noise ratio of such approach was investigated. The principle of the sensor design can significantly increase the intensity of the waves, reconstructed by the holograms of the sensor. The intensity distribution of the reconstructed waves is an Airy picture that changes only in intensity, which eliminates the errors of intensity measurements caused by the influence of aberrations.",
keywords = "Diffuse scattered beam, Fourier-hologram, Holographic wavefront sensor",
author = "Orlov, {V. V.} and Venediktov, {V. Yu} and Gorelaya, {A. V.} and Shubenkova, {E. V.} and Zhamalatdinov, {D. Z.}",
year = "2019",
month = "8",
day = "1",
doi = "10.1016/j.optlastec.2019.03.028",
language = "English",
volume = "116",
pages = "214--218",
journal = "Optics and Laser Technology",
issn = "0030-3992",
publisher = "Elsevier",

}

Measurement of Zernike mode amplitude by the wavefront sensor, based on the Fourier-hologram of the diffuse scattered mode. / Orlov, V. V.; Venediktov, V. Yu; Gorelaya, A. V.; Shubenkova, E. V.; Zhamalatdinov, D. Z.

В: Optics and Laser Technology, Том 116, 01.08.2019, стр. 214-218.

Результат исследований: Научные публикации в периодических изданияхстатья

TY - JOUR

T1 - Measurement of Zernike mode amplitude by the wavefront sensor, based on the Fourier-hologram of the diffuse scattered mode

AU - Orlov, V. V.

AU - Venediktov, V. Yu

AU - Gorelaya, A. V.

AU - Shubenkova, E. V.

AU - Zhamalatdinov, D. Z.

PY - 2019/8/1

Y1 - 2019/8/1

N2 - First experimental demonstration of the device, providing measurement of Zernike polynomial in the incoming wavefront by the use of the Fourier-hologram, recorded with the use of diffuse scattered beam. Signal to noise ratio of such approach was investigated. The principle of the sensor design can significantly increase the intensity of the waves, reconstructed by the holograms of the sensor. The intensity distribution of the reconstructed waves is an Airy picture that changes only in intensity, which eliminates the errors of intensity measurements caused by the influence of aberrations.

AB - First experimental demonstration of the device, providing measurement of Zernike polynomial in the incoming wavefront by the use of the Fourier-hologram, recorded with the use of diffuse scattered beam. Signal to noise ratio of such approach was investigated. The principle of the sensor design can significantly increase the intensity of the waves, reconstructed by the holograms of the sensor. The intensity distribution of the reconstructed waves is an Airy picture that changes only in intensity, which eliminates the errors of intensity measurements caused by the influence of aberrations.

KW - Diffuse scattered beam

KW - Fourier-hologram

KW - Holographic wavefront sensor

UR - http://www.scopus.com/inward/record.url?scp=85063407611&partnerID=8YFLogxK

U2 - 10.1016/j.optlastec.2019.03.028

DO - 10.1016/j.optlastec.2019.03.028

M3 - Article

AN - SCOPUS:85063407611

VL - 116

SP - 214

EP - 218

JO - Optics and Laser Technology

JF - Optics and Laser Technology

SN - 0030-3992

ER -