Effect of the Degradation of Ion-Exchange Resins on the Quality of High-Purity Water Prepared by Ion-Exchange Deionization

Результат исследований: Научные публикации в периодических изданияхстатья

1 цитирование (Scopus)

Выдержка

In the course of water deionization on ion-exchange filters of mixed action, charged with a mixture of KU-2×8 ch.s. cation exchanger and AV-17×8 ch.s. anion exchanger, which are ion-exchange resins of nuclear class, the water being treated is contaminated with soluble organic substances originating from degradation of the resins. Their concentration can reach 20 μg L–1, gradually decreasing to 5–6 μg L–1. Procedures were suggested for determining soluble organic substances washed out from the ion-exchange filters, including gravimetric determination of their sum in aqueous extracts from the organic ion exchangers, spectrophotometric determination in water being purified on the ion exchangers, and preconcentration of electrically charged forms of soluble organic substances by electroosmosis.
Язык оригиналаанглийский
Страницы (с-по)767-770
ЖурналRussian Journal of Applied Chemistry
Том89
Номер выпуска9
DOI
СостояниеОпубликовано - 2016
Опубликовано для внешнего пользованияДа

Отпечаток

Ion exchangers
Ion exchange
Degradation
Organic ion exchangers
Water
Electroosmosis
Ion Exchange Resins
Ion exchange resins
Anions
Cations
Negative ions
Resins
Positive ions

Цитировать

@article{1687ec1bdb924b819048d8bc15843f73,
title = "Effect of the Degradation of Ion-Exchange Resins on the Quality of High-Purity Water Prepared by Ion-Exchange Deionization",
abstract = "In the course of water deionization on ion-exchange filters of mixed action, charged with a mixture of KU-2×8 ch.s. cation exchanger and AV-17×8 ch.s. anion exchanger, which are ion-exchange resins of nuclear class, the water being treated is contaminated with soluble organic substances originating from degradation of the resins. Their concentration can reach 20 μg L–1, gradually decreasing to 5–6 μg L–1. Procedures were suggested for determining soluble organic substances washed out from the ion-exchange filters, including gravimetric determination of their sum in aqueous extracts from the organic ion exchangers, spectrophotometric determination in water being purified on the ion exchangers, and preconcentration of electrically charged forms of soluble organic substances by electroosmosis.",
author = "Moskvin, {L. N.} and Rakov, {V. T.} and Yakimova, {N. M.}",
year = "2016",
doi = "DOI: 10.1134/S1070427216060136",
language = "English",
volume = "89",
pages = "767--770",
journal = "Russian Journal of Applied Chemistry",
issn = "1070-4272",
publisher = "МАИК {"}Наука/Интерпериодика{"}",
number = "9",

}

Effect of the Degradation of Ion-Exchange Resins on the Quality of High-Purity Water Prepared by Ion-Exchange Deionization. / Moskvin, L. N.; Rakov, V. T.; Yakimova, N. M.

В: Russian Journal of Applied Chemistry, Том 89, № 9, 2016, стр. 767-770.

Результат исследований: Научные публикации в периодических изданияхстатья

TY - JOUR

T1 - Effect of the Degradation of Ion-Exchange Resins on the Quality of High-Purity Water Prepared by Ion-Exchange Deionization

AU - Moskvin, L. N.

AU - Rakov, V. T.

AU - Yakimova, N. M.

PY - 2016

Y1 - 2016

N2 - In the course of water deionization on ion-exchange filters of mixed action, charged with a mixture of KU-2×8 ch.s. cation exchanger and AV-17×8 ch.s. anion exchanger, which are ion-exchange resins of nuclear class, the water being treated is contaminated with soluble organic substances originating from degradation of the resins. Their concentration can reach 20 μg L–1, gradually decreasing to 5–6 μg L–1. Procedures were suggested for determining soluble organic substances washed out from the ion-exchange filters, including gravimetric determination of their sum in aqueous extracts from the organic ion exchangers, spectrophotometric determination in water being purified on the ion exchangers, and preconcentration of electrically charged forms of soluble organic substances by electroosmosis.

AB - In the course of water deionization on ion-exchange filters of mixed action, charged with a mixture of KU-2×8 ch.s. cation exchanger and AV-17×8 ch.s. anion exchanger, which are ion-exchange resins of nuclear class, the water being treated is contaminated with soluble organic substances originating from degradation of the resins. Their concentration can reach 20 μg L–1, gradually decreasing to 5–6 μg L–1. Procedures were suggested for determining soluble organic substances washed out from the ion-exchange filters, including gravimetric determination of their sum in aqueous extracts from the organic ion exchangers, spectrophotometric determination in water being purified on the ion exchangers, and preconcentration of electrically charged forms of soluble organic substances by electroosmosis.

U2 - DOI: 10.1134/S1070427216060136

DO - DOI: 10.1134/S1070427216060136

M3 - Article

VL - 89

SP - 767

EP - 770

JO - Russian Journal of Applied Chemistry

JF - Russian Journal of Applied Chemistry

SN - 1070-4272

IS - 9